4000-520-616
欢迎来到免疫在线!(蚂蚁淘生物旗下平台)  请登录 |  免费注册 |  询价篮
BioMatrix(优势品牌)
主营:胶原蛋白、纤连蛋白、玻连蛋白、水性凝胶、低代成纤维细胞
咨询热线电话
4000-520-616
当前位置: 首页 > 产品中心 > Electrophysiological > 高级生物矩阵/Mebiol®//5180-10ML
商品详细高级生物矩阵/Mebiol®//5180-10ML
高级生物矩阵/Mebiol®//5180-10ML
高级生物矩阵/Mebiol®//5180-10ML
商品编号: 5180-10ML
品牌: BioMatrix
市场价: ¥7100.00
美元价: 4260.00
产地: 美国(厂家直采)
公司:
产品分类: 电生理设备
公司分类: Electrophysiological
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍

ProductDescription

Mebiol®ThermoreversIBLeHydrogelis10gramsofacopolymerofpoly(N-isopropylacrylamide)andpoly(ethyleneglycol)(PNIPAAm-PEG).ThedefiningfeatureofMebiol®isitstemperaturereversiblesol-geltransition.ChillMebiol®toturnitintoasol(meaningithandleslikealiquid).HeatMebiol®toturnitintoasolidhydrogel.Theuniquethermoreversiblefeatureallowsforextremelyeasycellhandling.CulturesareseededintocooledMebiol®andrecoveredconvenientlybycoolingtheculturevesselandcentrifugation.Inthegelstate,thehighlylipophilicandnetworkstructureoftheMebiol®presentsanefficientnicheforcellproliferation,cellcommunication,gasandmassexchange,andprotectionofcellsandtissuefromshearforces.

Mebiol®iseasytouse,non-toxic,100%syntheticandhashightransparency.Publishedapplicationsincludestemcellandpluripotentstemcellculture,expansion,anddifferentiation,spheroidculture,cellimplantation,organandtissueregeneration,drugdeliveryandmore.ThoughMebiol®suppressesfibroblastgrowth,ithasbeencommercializedasacell/tissueculturereagentforEScells,chondrocytesandcancercells.

Parameter,Testing,andMethodMebiol®ThermoreversibleHydrogel#5180
PackageSize10mL
FormLyophilized
StorageTemperaturesRoomtemperaturepriortosolubilization.Aftersolubilization,storeat2-8°Cfor1monthoraliquotat-20°Cforlongtermstorage
FluidTemperature0-15°C
GelTemperature>25°C
SterilizationMethodEthyleneOxide
ShelfLifeMinimumof6monthsfromdateofreceipt

DirectionsforUse

DownloadthefullPDFversionorcontinuereADIngbelow:

CoatingProcedure

CellcultureinMebiol®flask:

  1. Openpackageinsterileenvironmentandadd10mLofculturemediadirectlytoMebiol®flask.
  2. Closeflaskandlayinrefrigerator(2-10°C)for3hourstoallowMebiol®toabsorbmedia.
  3. PeriodicallyshakeflaskgentlytohelpdissolvetheMebiol®intothemedia.Maketakeuptoadayforcompletedissolution(maintainatcoldtemperature).
  4. Afterdissolving,allowtositinrefrigeratoruntilbubblesareeliminated.
  5. Addcells/tissuesintoMebiol®atlowtemperature(2-10°C)andwarmto37°Ctoculturecells/tissuesina3Dhydrogelenvironment.
  6. Torecoverthecells/tissues,cooltheMebiol®backdownanddilutewith30-40mLofcoldsalineormedium.Thiswilltakeitoutofgelphase.SUSPendedcellscanbeeasilyrecoveredviacentrifugation.

Cellculturein24-wellplate:

  1. Followsteps1-4above.
  2. Beforeaddingcells/tissues,removedesiredamountofMebiol®andputintochilledcentrifugetube.PutremainingMebiol®intorefrigerator(stillinoriginalflask).
  3. Addapproximately105cell/mLtochilledcentrifugetubeandmixgentlyonice.
  4. Warmup24-wellplateandseparateoverlayingculturemediato37°C.
  5. Add200µLofcoldMebiol®suspensiontothecenterofeachwell.MakesureMebiol®doesnotcoverentirebottomofthewelltomakeiteasiertochangeoverlaidmediuminlaterstep.
  6. Overlay400µLofwarmedculturemediacontainingphenolredonMebiol®suspension.Cultureat37°C.
  7. Torecovercells,refrigerateat2-8°Canddilutewith400µLofcoldsalineormedium.ThiswilltakeMebiol®outofgelphase.Suspendedcellscanbeeasilyrecoveredviacentrifugation.

Donotre-sterilizetoavoiddeterioration.Addmediapromptlyafteropening,storeinrefrigerationandusewithin1month.

ProductQ&A

Thereisawiderangeofmolecularweightdistribution,butthemolecularweightisatleast>100,000.

PhysicalPropertiesAsynthetichydrogelwiththermoreversiblegelation.II.:Effectofaddedsalts.H.Yoshioka,M.Mikami,Y.Mori,andE.Tsuchida.J.Macromol.Sci.,A31(1),121-125(1994).http://www.tandfonline.com/doi/abs/10.1080/10601329409349723#.UvFzqtKE1NQ

PhysicalPropertiesThermoreversiblegelationonheatingandoncoolingofanaqueousgelatin-poly(N-isopropylacrylamide)conjugate.,H.Yoshioka,Y.Mori,S.Tsukikawa,andS.Kubota,Polym.Adv.Tech.,9,155-158(1998).http://onlinelibrary.wiley.com/doi/10.1002/(SICI)1099-1581(199802)9:2%3C155::AID-PAT750%3E3.0.CO;2-G/abstract

PhysicalPropertiesASynthetichydrogelwiththermoreversiblegelation.I.Preparationandrheologicalproperties,H.Yoshioka,M.MikamiandY.Mori.J.M.S-PureAppl.Chem.,A31(1),pp.113-120(1994).http://www.tandfonline.com/doi/abs/10.1080/10601329409349722#.UvFK1dKE1NQ

PhysicalPropertiesPreparationofPoly(N-Isopropylacrylamide)-b-Poly(EthyleneGlycol)andCalorimetricAnalysisofitsAqueousSolution,H.Yoshioka,M.MikamiandY.Mori,J.M.S-PureAppl.Chem.,A31(1),pp.109-112(1994).http://www.tandfonline.com/doi/abs/10.1080/10601329409349721#.UvFLB9KE1NQ

PhysicalPropertiesAsynthetichydrogelwiththermoreversiblegelation.III.:AnNMRstudyoftheSol-Geltransition.H.Yoshioka,Y.MoriandJamesA.Cushman.Polym.Adv.Tech.,5,pp.122-127(1994).http://onlinelibrary.wiley.com/doi/10.1002/pat.1994.220050207/abstract

ProductReferences

Mebiol®References:

Aeby,EliseA.,etal."MicrofluidicHydrogelHanging‐DropNetworkforLong‐TermCulturingof3DMicrotissuesandSimultaneousHigh‐ResolutionImaging."AdvancedBiosystems2.7(2018):1800054.

Sudha,B.,etal."CultivationofhumancorneallimbalstemcellsinMebiolgel®-Athermo-reversiblegelationpolymer."IndianJournalofMedicalResearch124.6(2006):655.

Sitalakshmi,G.,etal."Exvivocultivationofcorneallimbalepithelialcellsinathermoreversiblepolymer(MebiolGel)andtheirtransplantationinrabbits:ananimalmodel."TissueEngineeringPartA15.2(2008):407-415.

Kataoka,Ken,andNam-hoHuh."Applicationofathermo-reversiblegelationpolymer,mebiolgel,forstemcellcultureandregenerativemedicine."Journalofstemcells&regenerativemedicine6.1(2010):10.

Madhavan,H.N.,etal."AstudyonthegrowthofcontinuousculturecelllinesembeddedinMebiolgel."CURRENTSCIENCE-BANGALORE-87(2004):1275-1277.

PARVEEN,NA,etal."Intraperitonealtransplantationofhepatocytesembeddedinthermoreversiblegelationpolymer(MebiolGel)inacuteliverfailureratmodel."(2008):275-280.

Kanda,Kazue,etal."Eccentricexercise-induceddelayed-onsetmusclesorenessandchangesinMarkersofmuscledamageandinflammation."Exerciseimmunologyreview19(2013).

ProductCertificateofAnalysis

Noresultfor.

ProductVideos

link to library blog - Mebiol<sup>®ThermoreversibleHydrogel
Mebiol®ThermoreversibleHydrogel

Video

SeeMore

SafetyandDocumentation

SafetyDataSheet

CertificateofOrigin

ProductDisclaimer

ThisproductisforR&Duseonlyandisnotintendedforhumanorotheruses.PleaseconsulttheMaterialSafetyDataSheetforinformationregardinghazardsandsafehandlingpractices.

品牌介绍
美国Advanced BioMatrix是3D组织培养、细胞检测和细胞增殖等领域实验解决方案的佼佼者。Advanced BioMatrix在分离、纯化、冻干、细胞培养和蛋白检测、多肽粘附、附着因子、基质硬度和其他3D matrix 产品开发方面有着丰富的经验。Advanced BioMatrix的研发经验和专业知识确保其产品可达到最佳质量,并保证产品之间一致性,方便研究客户使用。 以下为Advanced BioMatrix 3D Matrices 产品竞争优势: 1. 提供高纯度和成分确定的胞外基质; 2. 超过1000余篇文献引用PureCol产品,品质非常均一; 3. 在3D培养基领域可提供最全面的产品线; 4. 唯一可提供特异性刚性有机硅基板的公司(CytoSoft); 5. 唯一可提供可溶性丝纤蛋白的供应商(可运用于多种3D培养); 6. 如果客户首次接触3D胶原凝胶,Advanced BioMatrix还是唯一的预制胶原蛋白(PureCol EZ Gel)供应商。 以下产品为Advanced BioMatrix全球畅销品: 1. PureCol 牛源I型胶原蛋白 3 mg/ml #5005-100ML 2. Nutragen牛源I型胶原蛋白 6 mg/ml #5005-100ML 3. FibriCol 牛源I型胶原蛋白 10 mg/ml #5133-20ML 4. VitroCol 人源I型胶原蛋白 #5007-20ML 5. 弹性蛋白原 #5052-1MG 6. ECM Select Array kit Ultra-36 #5170-1EA 7. CytoSoft(刚性可变的基底,Advanced BioMatrix最新添加产品5190-7EA) 8. 人III型胶原蛋白 #5021-10MG 9. 人IV型胶原蛋白 #5022-5MG 10. Silk Fibroin溶液 #5154-20ML 11. Fibronectin #5080-5MG 12. Vitronectin #5051-0.1MG Advanced BioMatrix最畅销的产品是PureCol(5005-100ML)。目前已有上千发表的论文使用这款产品。(Nutragen 5010、fibricol 5133和PureCol的物质成分一样,仅仅是浓度不同)浓度越高,胶原蛋白硬度越强。